Gas Fired Kiln - LN2000
A large multi-purpose semi-muffled gas fired kiln for both the professional and student user. The LN2000 provides controlled heat up to a maximum temperature of approximately 1100°C.
Top Key Features
- Piezo Spark Ignition eliminates lighting problems
- Flame Failure Device means if there is no flame, there is no gas
- Heat Control Valve ensures simple, safe temperature control
- Unique Safety Door provides minimum heat exposure
Overview
A large multi-purpose semi-muffled gas fired kiln for both the professional and student user. The LN2000 provides controlled heat up to a maximum temperature of approximately 1100°C.
The LN2000 Gas Fired Kiln has many uses including pottery, metal heat treatment, enamelling, melting precious metals and wax burn-outs. It is used by students of jewellery, and laboratory technicians. It reaches 850°C in only 15 minutes and approximately 1000°C in 35 minutes.
Designed for use in well ventilated areas the LN2000 runs on natural gas or bottled gas (LPG) and the flush fitting hamber-sized door permits full use of all of the chamber volume. Requires 240V.
Key Features
- Piezo Spark Ignition eliminates lighting problems
- Flame Failure Device means if there is no flame, there is no gas
- Heat Control Valve ensures simple, safe temperature control
- Unique Safety Door provides minimum heat exposure
Dimensions
Width: | 480 mm |
---|---|
Height: | 655 mm |
Depth: | 340 mm |
Weight (Net): | 47 kg |
Weight (Gross): | 47 kg |
Internal Length: | 340 mm (Internal Depth) |
Internal Width: | 300 mm |
Internal Height: | 300 mm |
Technical Specifications
Electrical: | 240V AC (for temperature display) |
---|---|
Features: | Versatile Fast Efficient in use Simple to Install and Maintain Large Chamber |
Safety: | Appropriate PPE must be warn at all times when operating equipment Heat control valve Flame failure device (no flame means no gas) Safety door |
Warranty: | 2 Years |
PLEASE STATE GAS TYPE WHEN ORDERING
IMPORTANT NOTICE: ACCORDING TO THE HEALTH & SAFETY AT WORK ACT 1974, BS 4163 AND COSHH REGULATIONS IT IS MANDATORY THAT ALL FUMES MUST BE REMOVED AT SOURCE.
Performance
Forging Performance
Gas Type | Rate | BTU / HRS | kW | Pressure |
Natural gas | 0.6 m3/h | 11000 | 3.22 | 20 mbar |
Propane | 0.46 kg/h | 11000 | 3.22 | 35 mbar |
Butane | 0.46 kg/h | 11000 | 3.22 | 28 mbar |