Gas Fired Kiln - LN1000
A popular semi-muffled gas fired kiln for both the professional and student user.Â
Top Key Features
- Piezo Spark Ignition eliminates lighting problems
- Flame Failure Device means if there is no flame, there is no gas
- Heat Control Valve ensures simple, safe temperature control
Overview
A popular semi-muffled gas fired kiln for both the professional and student users. The LN1000 provides controlled heat up to a maximum temperature of approximately 1000°C. The LN1000 Gas Fired Kiln has many uses including metal heat treatment, enamelling, melting precious metals and wax burn-outs. It is used by students of jewellery, dental and laboratory technicians. The unit reaches 850°C in just 15 minutes and can reach approximately 1000°C in thirty five minutes.
The LN1000 is designed for use with natural gas or low pressure bottled gas, the LN1000 can be permanently installed. The constant heat input combined with space-age insulation produces a stable operating temperature with minimum gas usage. Requires 240V.
Key Features
- Piezo Spark Ignition eliminates lighting problems
- Flame Failure Device means if there is no flame, there is no gas
- Heat Control Valve ensures simple, safe temperature control
- Unique Safety Door provides minimum heat exposure
- Temperature Indicator
Dimensions
Width: | 280 mm |
---|---|
Height: | 410 mm |
Depth: | 280 mm |
Weight (Net): | 11.8 kg |
Weight (Gross): | 11.8 kg |
Internal Length: | 195 mm (Internal Depth) |
Internal Width: | 130 mm |
Internal Height: | 130 mm |

Technical Specifications
Electrical: | 240V AC (for temperature display) |
---|---|
Features: | Versatile Fast Efficient in use Simple to Install and Maintain |
Safety: | Appropriate PPE must be warn at all times when operating equipment Heat control valve Flame failure device (no flame means no gas) Safety door |
Warranty: | 2 Years |
PLEASE STATE GAS TYPE WHEN ORDERING
IMPORTANT NOTICE: ACCORDING TO THE HEALTH & SAFETY AT WORK ACT 1974, BS 4163 AND COSHH REGULATIONS IT IS MANDATORY THAT ALL FUMES MUST BE REMOVED AT SOURCE.
Performance
Forging Performance
Gas Type | Rate | BTU / HRS | kW | Pressure |
Natural gas | 0.3 m3/h | 11000 | 33.22 | 20 mbar |
Propane | 0.23 kg/h | 5,000 | 3.22 | 35 mbar |
Butane | 0.23 kg/h | 5,000 | 3.22 | 28 mbar |
Â